Passer au contenu

Panier

Votre panier est vide

Explorer nos produits

20x4 Character LCD STN Transflective - MCU

SKU: DM-LCD2004-442
Prix de vente$24.90
  • 💹 Enjoy a 20% discount for orders over 500
  • 📉 A 15% discount is available for orders ranging from 200 to 499
  • 🎁 A 10% discount is available for orders ranging from 50 to 199
  • 🎁 A 5% discount is available when ordering 10-49

Interested in customizing this product? Get in touch with us.

Order samples, immediate delivery.

Factory bulk lead time: 3 weeks.

Color: Yellow Green

Partager
A 20-character x 4-line LCD module
20x4 Character LCD STN Transflective - MCUYellow Green Prix de vente$24.90

Resources & Downloads

Engineering Product Brief

20x4 Character LCD STN Transflective Display Module with MCU Interface

DM-LCD2004-442 is a 20 characters × 4 lines character LCD module using STN positive yellow-green transflective display technology. It is intended for embedded equipment panels that require text display, a 5V module supply, and a 6800 series MPU interface.

The module uses an ST7066U controller IC. The product information lists 8-bit and 4-bit MPU interface mode support, allowing the host design to select a wider data bus or a reduced-pin connection after timing and firmware review.

20 × 4Character format for four-line text information
STN PositiveYellow-green transflective LCD mode
ST7066UController IC listed for this display module
5.0VPower supply range listed as 4.5V to 5.5V
DM-LCD2004-442 20x4 character LCD module mechanical dimension drawing
SKUDM-LCD2004-442
View Direction6:00 direction
Module Size98.0 × 60.0 × 13.6(MAX) mm
BacklightYellow Green LED
Temperature-20°C to +70°C operation

Verified Technical Specifications

The parameters below are organized for engineering review, purchasing comparison, mechanical planning, and sample evaluation. Confirm the selected color option and latest documentation before ordering.

Parameter Specification
Product Model DM-LCD2004-442
Product Type 20x4 character LCD module
Display Format 20 characters × 4 lines
Display Mode STN Positive, Yellow Green, Transflective
Module Dimension 98.0 × 60.0 × 13.6(MAX) mm
View Direction 6:00
Power Supply 5.0V, operating range 4.5V to 5.5V
Backlight Yellow Green LED
Interface 6800 Series MPU Interface
Interface Mode 8-bit and 4-bit MPU interface modes listed on the product page
Controller IC ST7066U
Duty / Bias 1/16 duty cycle, 1/5 bias ratio
Contrast Ratio 3:1 typical
Response Time 300–400 ms
Logic Current 1.2 mA typical
Backlight Current 280 mA at 4.2V
Operating Temperature -20°C to +70°C
Storage Temperature -30°C to +80°C
Weight 69.6 g

Optical and Display Review

The transflective LCD structure is suitable for projects that need visibility review under ambient light and backlight-assisted conditions. Final readability depends on the enclosure, cover material, contrast setting, viewing angle, and lighting environment.

The listed 6:00 view direction should be compared with the final mounting position. For operator panels, handheld instruments, and equipment interfaces, verify the real viewing posture during sample testing.

Character Display Format

20 characters × 4 lines provides more text capacity than common 16x2 character LCD modules for menus, status lines, and measurement labels.

Contrast and Response

The page-listed values are 3:1 typical contrast ratio and 300–400 ms response time. Review these values for static text display applications.

Duty and Bias

The module information lists 1/16 duty and 1/5 bias. These values should be reviewed together with contrast adjustment and LCD driving behavior.

Backlight Current

The yellow-green LED backlight current is listed as 280 mA at 4.2V. Check the driver capacity and power budget during system design.

Controller and Interface Notes

The module uses an ST7066U controller IC and a 6800 series MPU interface. Use the official controller documentation to confirm initialization sequence, timing requirements, command behavior, and 4-bit or 8-bit interface configuration.

1
Host MCU Review

Confirm host logic compatibility, available GPIO count, and firmware timing before selecting 4-bit or 8-bit operation.

2
6800 Series MPU Interface

Review the interface pins, control signals, and timing details against the official datasheet and host-board schematic.

3
Contrast Adjustment

Set the VO pin correctly during bring-up. Incorrect contrast adjustment can make characters difficult to read.

4
Sample Validation

Validate display readability, backlight current, and operating temperature behavior in the final enclosure.

Interface Selection The product page lists both 8-bit and 4-bit MPU interface modes. Select the mode according to available MCU pins and firmware design.
Controller Documentation Use the ST7066U document linked below for controller-level details. Do not rely only on the product summary for firmware implementation.
Power-On Review Check display initialization after power-on with the final host board, supply ramp, and contrast circuit.
Mechanical Interface Use the mechanical drawing and module dimension to confirm mounting hole position, PCB clearance, and front-window alignment.
Color Variant The specification table focuses on DM-LCD2004-442. Confirm the exact model and display appearance if evaluating alternative color versions.
Ordering Confirmation Confirm datasheet revision, sample availability, bulk lead time, and the intended variant with DisplayModule before production ordering.

Electrical and Operating Conditions

Use the following values for early system review. Final suitability should be confirmed with samples under the real enclosure, cable, power, and ambient-light conditions of the end product.

Module Power 5.0V nominal, with 4.5V to 5.5V range listed for the module.
Logic Current Typical logic current is listed as 1.2 mA.
Backlight Current Backlight current is listed as 280 mA at 4.2V.
Temperature Range Operation: -20°C to +70°C. Storage: -30°C to +80°C.

Project Fit Checklist

Use this checklist before sample approval, PCB release, and purchasing confirmation.

Confirm that 20 characters × 4 lines are sufficient for the user interface content.
Confirm 6800 series timing and 4-bit or 8-bit wiring before PCB routing.
Reserve contrast adjustment access and validate VO setting during sample bring-up.
Review backlight current, available power budget, and thermal conditions in the final product.

Industrial Control Panels

Evaluate for machine status panels, process displays, and equipment interfaces where text readability is required.

Test and Measurement

Can be evaluated for data loggers, calibration tools, laboratory instruments, and equipment that displays stable text or numeric values.

Embedded Equipment

Use in host systems that can provide the required 5V supply, MCU bus signals, and module mounting space.

Portable Instruments

Evaluate logic current, backlight current, ambient-light readability, and operating temperature range against the final use case.

Engineering Notes Before Ordering

These review points help reduce integration risk before firmware, PCB layout, enclosure design, and purchasing decisions are finalized.

01

Power and Backlight

Confirm the 5V module supply, backlight drive method, and current budget. Include the listed backlight current in power planning.

02

Firmware Bring-Up

Review ST7066U initialization, selected interface mode, and timing margins using the official controller documentation.

03

Contrast Setting

Plan VO contrast adjustment and validate readability under expected temperature and lighting conditions.

04

Mechanical Envelope

Use the 98.0 × 60.0 × 13.6(MAX) mm module dimension together with the drawing when checking enclosure clearance.

05

Variant Selection

Confirm the exact display appearance, documentation, and selected model if evaluating alternative model specifications.

06

Production Release

Confirm sample availability, bulk lead time, price tier, and lifecycle status with DisplayModule before production ordering.

FAQ for Engineering and Purchasing Teams

The answers below support early selection review. For production projects, confirm the latest datasheet, selected variant, and order conditions before release.

Is this module designed for graphics?

No. This is a 20 characters × 4 lines character LCD module for text, numbers, symbols, menus, and equipment status information.

Which controller IC is used?

The product specification lists ST7066U. Use the official controller document below for controller-level implementation details.

What supply voltage should be used?

The module specification lists 5.0V power supply with a 4.5V to 5.5V range. Check host-board power tolerance and backlight drive separately.

What temperature range is listed?

The operating temperature is listed as -20°C to +70°C, and the storage temperature is listed as -30°C to +80°C.

Can it be used in ambient light?

The module is listed as transflective, so it can be evaluated for ambient-light readability. Final suitability depends on enclosure, cover material, viewing angle, contrast setting, and lighting conditions.

Can the exact model be customized?

The product page lists customization options such as backlight options, modified viewing angles, bulk order programs, and extended temperature versions. Confirm the scope before ordering.

Engineering Files and Official Documentation

Download the official product datasheet, alternative model specification, and ST7066U controller documentation to confirm dimensions, electrical requirements, interface behavior, controller functions, and integration notes before sample evaluation or production ordering.

Reviews from our customers