6-inch graphic LCD with 320x240 resolution, interfaced with MCU
320x240 Graphic LCD 6" - MCUBlack White Sale price$129.00

Resources & Downloads

DM-LCD320240-477 / 478 · S1D13700

A 320 × 240 graphic LCD with an MCU bus

The DM-LCD320240-477 and DM-LCD320240-478 combine a 320 × 240 monochrome graphic display with an S1D13700 controller and an eight-bit parallel host interface. The 6-inch product family provides room for multi-line readouts, menus and graphical information.

Choose the black-and-white 477 for its positive FSTN transflective display, or the blue 478 for its negative STN transmissive display. Both use a 20-pin module connection, with separate considerations for logic power, LCD contrast and white-LED illumination.

320 × 240Graphic pixel matrix
8-bit parallel6800 / 8080 host
S1D13700Display controller
20 pinsModule connection
DM-LCD320240-478 blue-module mechanical drawingOpen full-size drawing ↗
DM-LCD320240-478 blue-module mechanical drawing

Select the optical version

Black and white: 477

The 477 uses positive FSTN and a transflective optical mode. Its contrast ratio is 5:1 typical, with a 450 ms typical response at 25°C. Evaluate the chosen front window, lighting and viewing position together when designing the finished assembly.

Blue: 478

The 478 uses negative STN and a transmissive optical mode. Its contrast ratio is 3:1 typical, with a 300 ms typical response at 25°C. Color choice therefore also selects a different optical configuration, not simply a different software palette.

Interpret the light-output figure

Both module documents list 380 cd/m² minimum and 420 cd/m² typical luminance with the condition “without LCD.” Those figures characterize the backlight condition stated in the table; they are not a finished-screen brightness rating.

Technical specifications

Parameter Specification
Variants 477: black/white, FSTN positive transflective; 478: blue, STN negative transmissive
Resolution / duty 320 × 240 pixels / 1/240 duty
Controller / interface S1D13700 / 8-bit parallel MPU
Logic supply 4.5 V minimum / 5.0 V typical / 5.5 V maximum
Logic current at 5 V 65 mA minimum / 75 mA typical / 80 mA maximum
LED forward voltage 3.4 V minimum / 3.5 V typical / 3.6 V maximum
LED forward current 128 mA typical / 160 mA maximum
Module outline 160 × 109 × 13 mm maximum thickness
Weight 477: 181.1 g; 478: 179.5 g
Viewing direction 6 o’clock
Contrast ratio 477: 5:1 typical; 478: 3:1 typical
Response at 25°C 477: 450 ms typical / 650 ms maximum; 478: 300 ms typical / 400 ms maximum
Temperature limits Operating −20 to +70°C; storage −30 to +80°C

Values apply to the named module or variant and the stated conditions. Typical values are not maximum ratings. Operating and storage temperature ranges are separate limits.

Connect the S1D13700 host bus

Data and command selection

DB0–DB7 carry the eight-bit bus. A0 distinguishes the controller access type, with chip-select, reset and read/write controls alongside it. Use the module pin description and S1D13700 command reference together when implementing controller transactions.

6800 or 8080 signaling

SEL selects the host-bus convention: high for 6800 and low for 8080. The read/write pins have mode-dependent roles. Match those roles and the strobe timing to the selected host peripheral before issuing initialization commands.

Check the logic thresholds

At the specified 5 V operating condition, the input-high threshold is 3.5 V minimum. A 3.3 V host output does not meet that stated threshold by nominal voltage alone. Provide an appropriate logic-level interface and check both write and read paths.

Mechanical integration

Fit the complete assembly

The 160 × 109 mm assembly requires space beyond the visible image for mounting, connections and component depth. The illustrated 478 drawing shows the blue version; the separate 477 PDF supplies the black-and-white version’s mechanical reference. Use the complete drawing for bezel placement and rear clearance.

Open the matching mechanical reference

Use the module document for the connector, mounting features, full profile and tolerances. Keep the selected variant and assembly level consistent across the electrical and enclosure design.

Open module specification and drawings ↗

Power, contrast and startup

Separate the LED drive

The white backlight has a 3.5 V typical forward voltage and 128 mA typical forward current. Use an appropriate current-controlled LED circuit. The 75 mA typical logic-current figure is separate and does not represent the complete illuminated assembly.

Set LCD contrast correctly

V0 is the contrast-related connection, while VEE is identified as a negative-voltage output. Follow the module contrast circuit instead of treating every power-named pin as an external supply input. Check adjustment across the intended operating conditions.

Initialize before application graphics

Configure the controller’s display and memory organization for the 320 × 240 panel, respecting reset and host-access timing. Start with a simple bounded graphic and text test, then check orientation, contrast and the chosen update method.

DM-LCD320240-477 engineering FAQ

What distinguishes this from the 14-pin 475 module?

These 477/478 modules expose an S1D13700-based eight-bit command/data host interface through 20 pins. The 475 has a different scan-signal connection. The same resolution and family size do not make the host wiring interchangeable.

Can a 3.3 V MCU connect directly to the inputs?

The module electrical table specifies a 3.5 V minimum input-high threshold at its stated 5 V condition. Use a suitable level interface and verify the host and module limits; do not assume direct compatibility from the MCU label.

Does the LED use the 5 V logic rail directly?

The LED forward voltage is 3.5 V typical, with 128 mA typical forward current. Provide the appropriate current-controlled backlight circuit, separately from the module’s nominal 5 V logic-supply connection.

Is the display rated at 420 cd/m²?

The 420 cd/m² typical value is explicitly listed without the LCD. It should not be treated as assembled-screen luminance. Evaluate the full optical stack and selected 477 or 478 version for the intended viewing conditions.

How is the host-bus mode selected?

The module pin description assigns high SEL to 6800 and low SEL to 8080. Select the hardware mode and then use the matching read/write signal roles and timing in the host driver.

Do both colors use the same mechanical drawing?

Both specifications list a 160 × 109 mm outline and 13 mm maximum thickness. The displayed drawing is labeled for the 478 blue version. Use the selected SKU’s PDF for its complete mounting, connection and tolerance details.

Download Official Datasheets & Resources

Use the 477 or 478 module datasheet for the selected optical version, connection and electrical limits. The S1D13700 document provides the controller programming reference.