Yellow-green 461
The 461 uses a positive STN, transflective display and yellow-green LEDs. Its backlight is specified at 4.2 V typical and 330 mA typical. Use the 461 drawing for the listed 87 mm board width and the complete assembly profile.







128x64 LCD Graphic Display 3.24" Monochrome - MCU
DM-LCD12864-461 / 462 · RA6963
The DM-LCD12864-461 and DM-LCD12864-462 use an RA6963 controller and an eight-bit parallel MCU interface for a 128 × 64 graphic image. The 3.24-inch product family offers yellow-green positive STN or blue negative STN versions.
The two versions share a pixel matrix and controller family, but their mechanical outlines and LED requirements differ. Select the exact SKU before designing the enclosure, backlight circuit and host connection.
Open full-size drawing ↗The 461 uses a positive STN, transflective display and yellow-green LEDs. Its backlight is specified at 4.2 V typical and 330 mA typical. Use the 461 drawing for the listed 87 mm board width and the complete assembly profile.
The 462 uses a negative STN, transmissive display and white LEDs. Its backlight is specified at 3.5 V typical and 64 mA typical. Its listed 89 mm board width differs from the 461, so both mounting and LED drive deserve a SKU-specific check.
The luminance figures in both documents are specified without the LCD: 200 cd/m² typical for the 461 and 550 cd/m² typical for the 462. They must not be treated as finished-screen brightness or used alone to compare complete display readability.
DB0–DB7 form the byte-wide bus, with C/D, RD, WR and CE controlling access. RESET is a separate active-low input. Follow the RA6963 command and status flow together with the module’s timing table when implementing transactions.
MD2 provides a column-selection input, while FS1 selects the font width: high for 6 × 8 and low for 8 × 8. Keep these hardware settings consistent with the controller memory layout and the application’s chosen text and graphics organization.
The input-high threshold is specified as 0.8 × VDD. At a 5 V module supply, evaluate host outputs against that threshold rather than assuming a nominal 3.3 V signal is sufficient. Check read-data levels as well as control and write signals.
| Parameter | Specification |
|---|---|
| Optical versions | 461: yellow-green positive STN, transflective; 462: blue negative STN, transmissive |
| Resolution / duty | 128 × 64 pixels / 1/64 duty |
| Controller / connection | RA6963 / 20 pins, 8-bit parallel MPU |
| Logic supply | 3.0 V minimum / 5.5 V maximum; 5 V nominal |
| Logic current at 5 V | 12 mA minimum / 16 mA typical / 18 mA maximum |
| 461 outline / weight | 87 × 70 × 13.6 mm maximum thickness / 66 g |
| 462 outline / weight | 89 × 70 × 13.6 mm maximum thickness / 75.3 g |
| 461 LED voltage / current | 4.0 / 4.2 / 4.4 V min/typ/max; 297 / 330 / 396 mA min/typ/max |
| 462 LED voltage / current | 3.4 / 3.5 / 3.6 V min/typ/max; 64 mA typical / 80 mA maximum |
| Viewing direction / contrast | 6 o’clock / 3:1 typical |
| Response time | 450 ms typical / 650 ms maximum at 25°C |
| Temperature limits | Operating −20 to +70°C; storage −30 to +80°C |
Values apply to the named module or variant and the stated conditions. Typical values are not maximum ratings. Operating and storage temperature ranges are separate limits.
The displayed mechanical drawing belongs to the yellow-green 461. Use the blue 462 PDF when designing for that variant. Check the complete frame profile, mounting holes, connector access and component height; the main-feature board dimensions alone do not replace the detailed assembly drawing.
Use the module document for the connector, mounting features, full profile and tolerances. Keep the selected variant and assembly level consistent across the electrical and enclosure design.
The pinout distinguishes the V0 contrast connection from the VEE negative-voltage output. Use the corresponding module circuit to establish contrast and keep those roles clear when assigning connector pins. Contrast adjustment and LED brightness are separate controls.
Configure the RA6963 display organization, text and graphic addresses for the 128 × 64 module and selected font setting. Observe controller status before transfers where required by the command reference. A correct electrical bus still needs consistent memory settings.
Begin with a clear screen, a text line and a bounded graphic to check orientation and addressing. Inspect the image at the intended 6 o’clock viewing orientation, then evaluate contrast and illumination with the enclosure window in place.
The specified LED requirements differ substantially: 461 is 4.2 V and 330 mA typical; 462 is 3.5 V and 64 mA typical. Design the current-controlled drive for the exact variant rather than copying one color’s settings to the other.
The main-features tables list 87 × 70 mm for the 461 and 89 × 70 mm for the 462, both with 13.6 mm maximum thickness. Use each full mechanical drawing for the complete frame, board and connector envelope.
The specified input-high threshold is 0.8 × VDD. Check the resulting requirement against the host’s guaranteed output levels and provide level interfacing where needed. A shared MCU interface name does not establish voltage compatibility.
FS1 selects high for a 6 × 8 font and low for an 8 × 8 font in the module pin description. Coordinate that choice with the RA6963 initialization and the application’s text layout.
The module identifies VEE as a negative-voltage output. Use the specified contrast circuit with V0 and follow the actual pin assignments. Do not interchange the generated output and contrast-control connection.
The 462 optical table gives 550 cd/m² typical with the condition “without LCD.” It is not a finished-screen luminance claim. Evaluate the complete negative-STN display and front window under the intended lighting.
Use the 461 or 462 module datasheet for the selected display, mounting and LED circuit. The RA6963 reference covers controller commands, status and display-memory organization.